Dilip Bhogale

dilipyb@rediffmail.com

Senior Inspection engineer

H2, Building no.17, Room No.135, Near IIT hospital, IIT Powai, Mumbai - 400 076, India

Address and contact information:

H2, Building no.17, Room No.135, Near IIT hospital, IIT Powai
Mumbai, Outside US
400 076
India
+91 22 2572 8275 / 98207 76895

Education:

Diploma in Mechanical Engineering, ASNT Level II UT, RT and CWI from ISNT.

Work experience:

· Co-ordinating of Inspection activities. · Inspection of Pipe laying activities at Valsad for GAIL DUPL Project. · Inspection of Large dia Spiral welded pipes, Procedure and Welder Qualification and QA/QC documentation of QGX Project at Chiyoda Technip Joint Venture, Ras Laffan,Qatar on behalf of Technip, Abu Dhabi. · Inspection of Manual and Hydraulically / Pnematically actuated ball valves at Dresser & Tormene, Italy on behalf of Punj Lloyd for TOTAL, France. · Inspection of Line pipes (Helical Seam Submerged Arc Welding) 36’’ OD x 15.88 mm WT - 80 Kms, as per API 5L Gr. X 70 at M/s. Welspun Gujarat Stahl Rohren Ltd, Anjar for PGN, Indonesia. · Inspection of Line pipes (Longitudinal Seam Submerged Arc Welding) 30’’ OD x 14.3, 11.9 and 10.3 mm WT - 727 Kms, as per API 5L Gr. X 70 at M/s. Welspun Gujarat Stahl Rohren Ltd, Bharuch and SAW Pipes limited, Mundra for AGIP Oil Company, Libya. · Inspection of Line pipes (Longitudinal Seam Submerged Arc Welding) 18’’ OD x 0.250’’ WT- 102 Kms, 18’’ OD x 0.218’’ WT - 0.5Kms, 18’’ OD X0.375’’WT-1.2 Kms, 18’’ OD X0.438’’WT - 0.5 Kms as per API 5L standard Gr. X 52 at M/s. Welspun Gujarat Stahl Rohren Ltd, Bharuch for Indian Oil Corporation Limited for their Koyali-Viramgam-Sidpur Pipe Line Project. · Inspection of LSAW Pipes at Saw Pipes Limited, Mathura - 24" OD x 22.mm WT, 36" OD x 30.2 mm, 33.3mm WT & API – 5L Gr 60 and Gr 65 & DNV 2000 specification for West Delta Deep Marine Concession, SCRAB - SAFFRON Development project. · Inspection of Multistage Pumps (15 Stage) at M/s.Kirloskar Ebara Pumps Ltd.,Kirloskarwadi. · Boiler inspection (4 coil type boilers) at Thermax in accordance with BS 1113 for UK, Navy. · Boiler inspection (Non Stamped – 40 TPH) at Thermax in accordance with ASME SEC - 1 for Conoco Phillips, Ireland refinery. · Inspection of Acid Resistance Bricks at Perfect Acid Wares, Jabalpur in accordance with IS: 4860 / 1968. · Inspection of Rubber Fenders at IRM, Ahmedabad in accordance with client specification for Abu Dhabi. · Inspection of Nylon,Polypropylene Ropes at Axiom Impex Limited, Boisar & Garware Wall Ropes Limited, Pune in accordance with BS: 4928, 5053, EN 699. · Inspection of Radar Test Platform at T.P.Technical Services, Ambarnath. · Inspection of ERW pipes at Surya Roshni Limited, Delhi as per API – 5L Specification. · Inspection of EFW pipes at Saw Pipes Limited, Mathura as per API – 5L & DNV - 2000 Specification. · Inspection of 3 LPE / FBE / Epoxy coated pipes at various SAW pipes manufacturer’s as per API – 5L2 / Client Specification. · Inspection of Feed Heater for Desalter Plant at ONGC, Ahemedabad. · Inspection of Fastners for ONGC offshore platform at various venders in Mumbai in accordance with ASTM A193 / A194. · Inspection of accessories & equipments for Railway Signalling System, IRAN at various sub-venders of SIEMENS (I) Ltd. · Preshipment inspection of Line pipes, Gas turbines for various clients in Iran, Egypt etc. · Inspection of line pipes as per API –5L, API-2B, ASTM A671, A672 - 406.4 (16”) TO 1422.4 (56”) thickness 6 mm to 32 mm. IS 3589,1239,1278 of 406.4 (16”) to 2540 (100”) and thickness 6 MM TO 20 MM. · Inspection of propylene / LPG bullet - 2450mm dia to 6078mm dia. Thickness upto 40mm as per BS 5500. · Inspeciton of columns from 24”OD TO 72”OD thickness upto 30mm, length upto 30 mtrs, Structurals to AWS D.1.1 and heavy structurals. · Inspection of Galvanised Structures, Holiday Tests for coating and painting. · Inspection of Machinery for Cement Plants Air Separator 4.5 Mtr Dia 12 Mtr Ht. · Quality Assurance & Inspection of Columns, structural, cement equipment as per client spec. Application of ASME SECTION II, V, VIII, IX, AWS D1.1, API - 5L, API 2B, API 1104, BS 5500, BSEN 287,288, IS 7307, 7310 · Quality Assurance & Inspection of SAW Pipes as per API-5L,API 2B, SA671, SA672, IS3589, IS1239, IS 1278. · Quality Assurance & Inspection of laying Large DIA Pipes i.e 2450 mm ID x 16mm Thk. For Dhabol Power Co., at Enron Dhabol site under Bechtel & Linghtec, USA. · Familiarity with welding processes SMAW, GMAW, SAW, GTAW · Preparation & Qualification of welding procedures, testing procedures, conversant with preparation & documentation of records as per API, ISO standards.

Skills, programming languages:

Specialized in Automatic NDT i.e. UT of plates, welds, tubes and Realtime RT of welds etc.

Professional references:

Mr. F.Majdinia (Inspection head)Technip, Abu-dhabi,N. Saito (QC engineer) CTJV, Ras Laffan, Qatar.

Link

Link to this resume: http://www.devresumes.com/resume/2573
© Digital Media Ventures LLC, 2006. Check out interview questions and discuss employers that are hiring.